It's a relief to have a Thorold, ON heating and air conditioning you can trust. Evans is always proud to show our creditials spanning over 50 years.
To replace a tankless hot water heater, homeowners in Thorold can anticipate paying between $1,300 - $4,100. This estimate includes labor and materials. Some benefits of tankless vs. standard tank water heaters include:
- Requires less storage space
- More energy efficient
- Hot water is available immediately
- Lifespan of unit is longer
For a quote on a new tankless water heater, contact us online today!
The average lifespan of a furnace and air conditioner unit, or an HVAC, is between 15 - 20 years. There are a few things you can do to increase the life of your unit:
- Change the air filter - Sounds simple, but it’s so important. Air filters that are clogged will not let the appropriate airflow to happen and can cause serious problems down the line.
- Schedule regular maintenance - Bi-annual service on your unit can give it extra years. It also helps it to run more efficiently and save you money in the process.
- Set realistic temperature goals - Overworking the system will shorten the unit’s lifespan.
Contact us online today for more information or to schedule a consultation!
There are a few reasons your AC is running but not cooling your Thorold home that you can easily check:
- Check the air filter and if it is dirty, change it. If airflow is blocked your system cannot properly cool your home.
- Is the condenser outside covered in dirt and debris? If so, your unit will have trouble dispersing the heat from your home.
- If the circuit breaker for the outside unit has tripped, the unit will keep running but not cooling. Try switching it back on but, if it trips again, you will need help from an electrician.
- Check to see if your thermostat is switched to the ON setting instead of the AUTO setting. ON will cause the unit to blow air constantly, even if it hasn’t cooled it yet.
If, after having tried these steps, your air is still blowing but not cooling, chances are you need a professional technician. Contact us online today for more information or to schedule an appointment.
One of the ways we show our reliability is through our Thorold, ON heating and air conditioning reviews. Check us out, and see for yourself.
Recent Jobs and Reviews in Thorold, ON
Our Local Reviews by City
- Allanburg, ON (3)
- Beamsville, ON (1)
- Crystal Beach, ON (3)
- Dunnville, ON (1)
- Fort Erie, ON (51)
- Grimsby, ON (14)
- Jordan Harbour, ON (1)
- Lincoln, ON (13)
- Niagara Falls, ON (925)
- Niagara-on-the-Lake, ON (178)
- Pelham, ON (53)
- Port Colborne, ON (18)
- Queenston, ON (14)
- Ridgeville, ON (5)
- Ridgeway, ON (7)
- Smithville, ON (4)
- St. Catharines, ON (261)
- St. Davids, ON (1)
- Thorold, ON (63)
- Vineland, ON (1)
- Vineland Station, ON (4)
- Virgil, ON (38)
- Wainfleet, ON (2)
- Welland, ON (73)
- West Lincoln, ON (2)
Job Locations and Reviews
We are so glad to hear that you had a good experience.
Cold water inlet assembly leaking, needs to be replaced. Will quote out a repair.
After hours service call , furnace repair . Cycled power and watched furnace operator for 20 mins no issues . Customer mention the hydro company had power off to the house short before furnace failed . Filter is a 6672( 5 inch filter about 10 months old ) furnace is operating with a 70 split . After cycling furnace off and back on with main power (120v ) multiple times the furnace did not come back on one of the times with 27 v going to terminal w and no error codes . If problem persist replace circuit board or furnace .installed new filter 6670 .
Lennox furnace maintenance. Found leaves in the intake just above burners . Cleaned and removed them . Performed maintenance on the unit . Found the humidifier filter was the incorrect one for this model , and the top tray was installed up side down . Install new #10 filter pad along with the furnace filter the customer provided . Both Units are operating very well with no issues .
Installed hot water tank and chimney liner
Evans Premier Furnace installation
Furnace maintenance and inspection
Lennox boiler repair. Pilot flame was partially clogged causing burners not to light consistently. Cleaned pilot and burners and put boiler back together. Pilot light is now much stronger and boiler is lighting consistently first try. No other problems found, working well at this time.
Keeprite furnace repair Furnace was cycling on high limit causing ecobee to recalibrate every morning. Airflow was being restricted by filter with high merv rating, filters were coming too restrictive in just a few weeks. Allergies, etc. are not a concern so a lower rated filter (merv8, merv11, etc.) is recommended to solve this issue. No problems found with the furnace itself.
Bryant furnace , error code 3.1 failed pressure switch . Verified drains and venting are clear of debris . All 3 pressure switched where closing . Furnace was not sending 24 volts to high pressure switch . I removed circuit board to inspect front and back , also tapping the relays . When I reinstalled board furnace operated without issue . C.0 in the exhaust was over 150 ppm , I adjusted gas pressure on high side down to 2.9 inw ( factory recommended 3.2 to 3.8 ) which brought c.o down to 70 ppm on low and high fire . Possible small blockage in secondary heat exchanger . If problem persist with pressure switch error the circuit board will be to be replace or the furnace .
Furnace installation
Furnace repair Furnace igniter would light, no flame. Gas valve is getting 24 volts. Wired gas valve directly to 24volt transformer to discover the gas valve is defective. Replaced gas valve and gas valve would partly open. Wired new gas valve directly to 24 volts and gas valve would open. Ensured gas valve was getting 24 volts and then inspected control board and found a small burn mark. Control board will require replacement as well. Customer is going to receive quotes on a new furnace.
Furnace and tankless maintenance and inspection. Both are working well and in good condition at this time.
Carrier furnace repair , inducer motor is starting to fail , recommended maintenance if he replaces motor
Furnace maintenance and inspection
Lennox furnace repair , installed new pressure switches tested unit for 12 mins
Lennox furnace maintenance, cleaned replaced and tested humidifier pad , furnace is operating good
Lennox furnace maintenance, furnace operating correctly , high fire pressure switch failed open , I have recommended to replace switched
Keeprite furnace maintenance , removed and cleaned condensation pump , removed inducer motor to check condition of collector box , test unit , furnace in good working order
Furnace maintenance and inspection
Furnace maintenance and inspection
Lennox furnace maintenance, no issuses found , unit in good working order, small amount of rust and calcium on top of water tank , no water present at the time , noticed old humidifier valve was not brazed closed ( brazed closed while there ) or possible leak from old cold water shut off ,would like a quote to replace shut and small length of copper pipe
Furnace Installation
Furnace maintenance. Furnace is in really good shape, found no issues or concerns.
Continental gas stove installation
Lennox furnace and ac maintenance, both units are operating great , I found no dye in the condenser or evaporator drain , refrigerant pressure are good and temperature differential is 15 f , same as last year